SKU# :
NV-CLR-024-10G
SKU
NV-CLR-024-10G
The Enterprise-Grade CLEER24-10G Ethernet Over Coax Switch Enables IP/IoT Devices up to 18 Times Farther Than Standard Power over Ethernet Switches
Skip to the end of the images gallery
- Contact Us : Tel: +44 (0)1296 719 582 / Email: sales@aldoussystems.co.uk
Skip to the beginning of the images gallery
- Contact Us : Tel: +44 (0)1296 719 582 / Email: sales@aldoussystems.co.uk
The NVT Phybridge CLEER24-10G Layer 3 Enterprise Grade switch is designed to make IP/IoT deployments simple, secure, and cost-effective. The CLEER24-10G switch delivers up to 50 Watts of power (PoE++) and 10/100 Mbps symmetrical, full-duplex, over coax cabling with up to 6,000ft (1,830m) reach.*
The CLEER24-10G switch enables Modern LAN principles and comes standard with 2 x SFP+ 10Gb/s uplink ports, dedicated management and console ports, 24 x 10/100 downlink ports, a 1,000 Watt hot-swappable power supply, power sharing, and power redundancy. The CLEER24-10G switch also comes with a new and intuitive GUI interface, ideal for any cloud or premise-based managed service offering. The new and improved CLI (Command Line Interface) is very similar to the Cisco offering for ease of use.
Benefits Include:
- Accelerate your return on investment by reducing infrastructure costs.
- Simplify your IP modernization, collapsing planning and deployment time.
- Eliminate infrastructure barriers, risks, disruption, and costs.
- Create a robust, secure IP platform that is easy to deploy and manage.
- Be environmentally responsible during your IP upgrades.
Speed, Reach and Power
CLEER24-10G switch delivers Fast Ethernet speeds and PoE++ (50W) over Coax with 6,000ft (1830m) reach. It is designed to support the most demanding IP endpoints with plenty of bandwidth to spare. The CLEER24-10G switch provides robust network performance at any distance.
Industry Leading PowerWISE® Technology
The NVT Phybridge CLEER24-10G switch is built with PowerWISE Technology, providing power sharing for redundancy, hot-swappable power supply, and auto-sensing 100-240 VAC delivering 1,000 Watts of power. The CLEER24-10G switch is one of the most energy efficient switches on the market, consuming 38 Watts of power to operate.
Security, Supporting Zero Trust Requirements
- 802.1x Port-Based Authentication, with supported EC adapter only*
- MAC security – static MAC locking per port
- Authentication, Authorization, and Accounting (AAA) with TACACS+ or RADIUS
- Remote monitoring
- SSH/SSL
- Multi-level user privilege controls
- Multi-layer access control lists
CLEER24-10G Technical Specifications
Model | CLEER24-10G | |||||||||||||||||||||
Part Number | NV-CLR-024-10G | |||||||||||||||||||||
Dimensions | 19 inches x 1U without rack ears:
• 1.73″ x 17.13″ x 11.22″ (HxWxD) • 4.39cm x 43.51cm x 28.49cm (HxWxD) |
|||||||||||||||||||||
Weight | 8 lb. (3.63 kg) | |||||||||||||||||||||
Mounting | Standalone, rack or shelf-mountable; 2 brackets included for installation | |||||||||||||||||||||
Processor | MIPS32 24KEc, 500MHz | |||||||||||||||||||||
Interface:
Ethernet Uplink |
Maximum 2 uplinks, each 10Gb/s (full-duplex):
2 SFP+ ports: 1000 Base-T/TX/SX/LX/EX/ZX, 10GBase-T/CU/SR/LR/ER/ZR (determined by SFP or SFP+ transceiver module installed), Ethernet IEEE 802.3z, fiber optic cable/UTP Note: The management port can be configured to be used as an uplink port, please see the admin guide for additional details. |
|||||||||||||||||||||
Interface:
Downlink (PoE and IP to Adapter) |
24 x BNC Jacks
Speed: 10/100Mb/s (full-duplex) PoE Power: 50 Watts Maximum per port Maximum Distance:
24 x Status LEDs: Configuration options: Link Activity / Link / Off |
|||||||||||||||||||||
Management | 1 LAN port (MGMT): RJ45, 10/100/1000 Base-T auto-sensing, IEEE 802.3
1 RS-232 console port: RJ45 to DB9 cable; Baud rate 115200/8/N/1 Note: The management port can be configured to be used as an uplink port, please see the admin guide for additional details. |
|||||||||||||||||||||
Power Supply* | Hot-Swappable Power Supply Unit
Auto-sensing 100-240VAC, 50/60 Hz |
|||||||||||||||||||||
Power Output | 1000W max at 100VAC
1000W max at 240VAC |
|||||||||||||||||||||
Power Consumption | Idle power draw: 38W | |||||||||||||||||||||
Power Injection (PoE) | DC voltage: 48VDC to 58VDC | |||||||||||||||||||||
PowerWISE® Power Sharing | 2 male connectors (rear)
DC IN and DC OUT: 48VDC to 58VDC |
|||||||||||||||||||||
Operating
temperature |
1000W Load: 14°F to 122°F (-10°C to +50°C)
500W Load: 14°F to 140°F (-10°C to +60°C) |
|||||||||||||||||||||
Humidity | 10% to 95% (non-condensing) at 95°F (35°C) | |||||||||||||||||||||
MTBF | 20 years |
CLEER24-10G Extended Technical Specifications
Operating System | Linux |
Layer 2 Features |
|
Switch Bandwidth | 44Gbps |
Packet Forwarding Rate | 32.6Mpps |
Priority Queueing | DRR |
Number of Priority Queues | 8 |
MAC Address Table Size | 32,000 |
Number of VLANs | 4K |
Number of Multicast Entries | 1K |
Layer 3 Features |
|
Max Static Routes | 128 (Shared between IPv4 and IPv6) |
Max SVI Routes | 4,000 (Shared between IPv4 and IPv6) |
Layer 4 Features | Protocol-Based VLANs |
Multicast | Supports IGMP snooping v1, v2, and v3 |
Security | • Authentication, Authorization, and Accounting (AAA)
o Built-in RADIUS client to co-operate with the RADIUS servers o RADIUS / TACACS+ login user access authentication • Remote Monitoring (RMON) • MAC Security • SSH / SSL • 802.1x Port-Based Authentication |
Management | • Management interface
o Web GUI switch management (HTTPS is supported) o Command line interface (CLI) o Serial console port o SNMP v1, v2c, v3 o SSH support • Multi-Switch management software is available • User privilege levels control • System maintenance o Firmware upload via CLI or GUI o Configuration upload/download via CLI or GUI o Hardware reset button for system reboot or reset to factory default • Network Time Protocol (NTP) • Link Layer Discovery Protocol (LLDP) • Link Layer Discovery Protocol Media Endpoint Discovery (LLDP-MED) • SNMP trap for interface linkup and linkdown notification • Event message logging to remote Syslog server |
CLEER24-10G Compliance & Agency Approval
EMC | Emissions: FCC Part 15, ICES-003, EN 55032:2012, EN 50121-4:2016
Class A Immunity: EN 55024:2010, EN 50121-4:2016 |
Safety | UL 60950-1 2nd Ed 2014-10-14, CAN/CSA C22.2 No. 60950-1-07 2nd Ed 2014-10
IEC 62368-1:2014, EN 62368-1:2014, AS/NZS 62368.1:2018 |
Environment | RoHS Directives 2011/65 and 2015/863 |
EC Adapter Options
There are three media converter options available to pair with the CLEER family of switches to extend PoE over Coax. The EC-Link and EC Link+ are single endpoint solutions and the EC4 enables 4 IP endpoints from a single long run Coax cable.
EC-LINK |
EC-LINK+ |
EC4 |
|
---|---|---|---|
Power |
|
|
|
Casing |
Plastic |
Metal |
Plastic |
EN 50121-4 Standard |
Yes – approved to operate in a railway/subway environment |
EC-Link Technical Specifications
Model | EC-Link |
Part Number | NV-ECLK |
Dimensions | 8.8cm x 3.2cm x 2.1cm (LxWxH);
3.46″ x 1.23″ x 0.83″ (LxWxH) |
Weight | 42g (1.48oz.) |
*802.1x Support | Not Applicable |
Interface: Network Infrastructure side (CLEER) | 1 BNC port: Coax cable (RG59, RG6, RG11) |
Line Speed | 10/100Mbps full duplex |
Interface: IEEE Side (IP Device) | 1 RJ45 port; device must be IEEE 802.3 af/at compliant |
Power Supply | PoE from the CLEER / EC switch or from EC-Base, maximum 30W over 2 pairs (spare pairs) |
DC IN | Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter with phoenix connector (IEC Class II isolated only) NOTE 1: Local power supply used must have its output isolated from Earth potential. NOTE 2: If voltage of local power supply is lower than the power voltage provided from the PoE switch, then power on the PoE switch should be turned off. |
Power Consumption | 0.9W |
Operating Temperature | -58°F to +158°F (-50°C to +70°C)
Tests conducted against international safety standard at maximum ambient temperatures of 50ºC |
Mean Time Before Failure (MTBF) | 20+ years |
Humidity | 10% to 95% (non-condensing) at 35° C |
EC-Link+ Technical Specifications
Model | EC-Link+ |
Part Number | NV-ECLK-PLS NV -ECLK-PLS-1X |
Dimensions | 10.09cm x 5.03cm x 2.57cm (LxWxH); 3.97” x 1.98” x 1.01” (LxWxH)” |
Weight | 108g (3.81oz.) |
*802.1x Support | Supported with adapter SKU: NV-ECLK-PLS-1X |
Interface: Network Infrastructure side (CLEER) | 1 BNC port: Coax cable (RG59, RG6, RG11) |
Line Speed | 10/100Mbps full duplex |
Interface: IEEE Side (IP Device) | 1 RJ45 port; adapter is IEEE 802.3af/at compliant and will negotiate power requirements with IP end device. |
Power Supply | Maximum 50W from CLEER / EC switch (If locally powered and 30W if power provided from switch) delivered on 4 pairs. |
DC IN (Barrel Connector) | Optional (sold separately) 48V – 56VDC via an external AC/DC Power Adapter (IEC Class II isolated only) with barrel connector NOTE 1: Local power supply used must have its output isolated from Earth potential. NOTE 2: If voltage of local power supply is lower than the power voltage provided from the PoE switch, then power on the PoE switch should be turned off.” |
Power Consumption | 1.1W |
Operating Temperature | -58°F to +158°F (-50°C to +70°C) Tests conducted against international safety standard at maximum ambient temperatures of 60ºC at 30W and 55ºC at 50W |
Mean Time Before Failure (MTBF) | 20+ years |
Humidity | 10% to 95% (non-condensing) at 35° C |
EC4 Technical Specifications
Model | EC4 |
Part Number | NV-EC-04 |
Dimensions | 11cm x 7cm x 2.5cm (LxWxH);
4.3” x 2.75” x 0.98” (LxWxH) |
Weight | 96g (3.38oz.) |
*802.1x Support | Not Applicable |
Interface: Network Infrastructure side (CLEER) | 1 BNC port: Coax cable (RG59, RG6, RG11) |
Line Speed | 100Mbps full duplex |
Interface: IEEE Side (IP Device) | 4 RJ45 ports: devices must be IEEE 802.3 af/at compliant |
Power Supply | PoE from the CLEER / EC switch or external power supply; maximum 50W (over 4-pairs) each port |
DC IN (Barrel Connector) | Optional (sold separately) 48V – 56VDC via an external AC/DC Power Adapter (IEC Class II isolated only) NOTE 1: Local power supply used must have its output isolated from Earth potential. NOTE 2: If voltage of local power supply is lower than the power voltage provided from the PoE switch, then power on the PoE switch should be turned off. |
Power Consumption | 1W |
Operating Temperature | -58°F to +158°F (-50°C to +70°C) Tests conducted against international safety standard at maximum ambient temperatures of 50ºC |
Mean Time Before Failure (MTBF) | 20+ years |
Humidity | 10% to 95% (non-condensing) at 35° C |
EC Adapters Compliance and Agency Approval
EMC | Emissions: FCC Part 15, ICES-003, EN 55032:2012, EN 50121-4:2015 Class A (EC4) Class B (EC-Link and EC-Link+) Immunity: EN 55024:2010, EN 50121-4:2015 |
Safety | UL 60950-1 2nd Ed 2014-10-14, CAN/CSA C22.2 No. 60950-1-07 2nd Ed 2014-10 IEC 62368-1:2014, EN 62368-1:2014, AS/NZS 62368.1:2018 |
Environment | RoHS Directives 2011/65 and 2015/863 |
SKU | NV-CLR-024-10G |
---|---|
Warranty | 2 Years |
Write Your Own Review
More from NVT Phybridge