2N
3CX
AVLinkPro
AVProEdge
Akuvox
Aldous Home Networks
Araknis Networks
Aten
AudioControl
Axion Lighting
Binary
BulletTrain
CasaTunes
Cerasonar
ClareVision
Cleerline
Coolautomation
ELAN
Episode
FrenchFlair Audio
Frenetik Audio
Furman
Fusion Research
Kordz
Leviton
Luma
MSolutions
Murideo
NVT Phybridge
Nice
Penn Elcom
Platinum Tools
Proficient
Pulse Eight
Rako
SpeakerCraft
Spectre Acoustics
Strong
Sunfire
Triax
Visualint
WattBox
Wirepath
Xantech
Yealink
eelectron
SKU# :
PE6108G
SKU
PE6108G
- Remote power outlet control (On, Off, Power Cycle) by individual outlets
- Real-time current, voltage, and kWH displayed in a browsed-based UI for monitoring at the PDU level
- Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices Management
- Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Skip to the end of the images gallery
- Contact Us : Tel: +44 (0)1296 719 582 / Email: sales@aldoussystems.co.uk
Skip to the beginning of the images gallery
- Contact Us : Tel: +44 (0)1296 719 582 / Email: sales@aldoussystems.co.uk
• 8 outlets
• 10A
• PDU Power Measurement
The PE6108 eco PDU is intelligent PDUs that contains 8 AC outlets and is available in various IEC or NEMA socket configurations. It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors*.
The eco PDUs offer remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs at the PDU device level from practically any location via a TCP/IP connection.
The eco PDU supports any 3rd party v3 SNMP Manager Software and The eco Sensors (Energy Management Software). The eco Sensors provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. With ALTUSEN eco Sensors, the Sensor-enabled eco PDU also offers comprehensive power analysis reports which can separate by departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display.
With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.
*Sensors are optional accessories. A sensor-enabled installation is required to generate a more complete energy-efficient data and chart. Higher sensor installation density is helpful to generate more accurate data.
Power Distribution Unit
Function | PE6108A | PE6108B | PE6108G |
Electrical | |||
Nominal Input Voltage | 100 – 120 VAC | 100 – 240 VAC | 100 – 240 VAC |
Maximum Input Current | 15A Max; 12A(UL de-rated) | 15A Max; 12A(UL de-rated) | 10A Max |
Input Frequency | 50-60 Hz | 50-60 Hz | 50-60 Hz |
Input Connection | NEMA 5-15P | NEMA 6-15P | IEC 60320 C14 |
Input Power | 1800 VA(Max); 1440 VA(UL de-rated) | 3120 VA(Max); 2496 VA(UL de-rated) | 2300 VA(Max) |
Outlet Type | Total: 8 x NEMA 5-15R | Total: 8 x IEC320 C13 | Total: 8 x IEC320 C13 |
Nominal Output Voltage | 100 – 120 VAC | 100 – 240 VAC | 100 – 240 VAC |
Maximum Output Current (Outlet) | NEMA 5-15R: 15A(Max); 12A(UL de-rated) | C13: 15A(Max); 12A(UL de-rated) | C13: 10A(Max) |
Maximum Output Current (Bank) | 15A(Max); 12A(UL de-rated) | 15A(Max); 12A(UL de-rated) | 10A(Max) |
Maximum Output Current (Total) | 15A(Max); 12A(UL de-rated) | 15A(Max); 12A(UL de-rated) | 10A(Max) |
Breakers | 1 x 15A Non-Fuse Breaker | 1 x 15A Non-Fuse Breaker | 1 x 15A Non-Fuse Breaker |
Metering | Bank level Current, Voltage, VA , PF and KWh Monitoring | Bank level Current, Voltage, VA , PF and KWh Monitoring | Bank level Current, Voltage, VA , PF and KWh Monitoring |
Outlet Switching | Yes | Yes | Yes |
Environment Sensor Ports | 2 | 2 | 2 |
Metering Accuracy | Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Physical Properties | |||
Dimensions (L x W x H) | 43.24 x 22.04 x 4.40 cm (17.02 x 8.68 x 1.73 in.) |
43.24 x 22.04 x 4.40 cm (17.02 x 8.68 x 1.73 in.) |
43.24 x 22.04 x 4.40 cm (17.02 x 8.68 x 1.73 in.) |
Weight | 2.77 kg ( 6.1 lb ) | 2.77 kg ( 6.1 lb ) | 2.77 kg ( 6.1 lb ) |
Power Cord Length | 3 m | 3 m | 3 m |
Environmental | |||
Temperature (Operating / Storage) | 0 – 50°C / -20 – 60°C | 0 – 50°C / -20 – 60°C | 0 – 50°C / -20 – 60°C |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing | 0 – 80% RH, Non-Condensing | 0 – 80% RH, Non-Condensing |
Compliance | |||
EMC Verification | FCC, Others by Request | FCC, Others by Request | CE, Others by Request |
Safety Verification | TUV-CB, cTUVus, Others by Request | TUV-CB, cTUVus, Others by Request | TUV-CB, CE-LVD, Others by Request |
Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |
- Power Distribution
- Space saving 1U rack mount design with rear mounting
- IEC or NEMA outlet models
- 3 digit 7-segment front panel LED shows Current / IP Address
- Remote users can monitor outlet status via web pages on their browsers
- Safe shutdown support
- Separate power for the unit's own power and its power outlets. The user interface is still accessible even when an overload condition trips the devices' circuit breaker
- Remote Access
- Remote power control via TCP/IP and a built in 10/100 Ethernet port
- Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
- eco PDU Power Management software – eco Sensors
- Supports SNMP Manager V3
- Operation
- Remote power outlet control (On, Off, Power Cycle) by individual outlets
- Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
- Easy setup and operation via a browser-based user interface
- Multibrowser support (IE, Firefox, Chrome, Safari)
- RTC support to keep the timer running during times of no power.
- Supports up to 8 user and 1 administrator accounts
- Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices
- Management
- Power status measurement at the PDU level
- LED indicators for current and IP address at the PDU device level
- Real-time current, voltage, and kWH displayed in a browsed-based UI for monitoring at the PDU level
- Current and voltage threshold setting
- Naming support for outlets
- User outlet access assignment on an outlet-by-outlet basis.
- Event logging and syslog support
- Upgradeable firmware
- Multilanguage support: English, German, Traditional Chinese, Simplified Chinese, Japanese, French, Spanish, Italian
- Security
- Two-level password security
- Strong security features include password protection and advanced encryption technologies – 128 bit SSL
- Remote authentication support: RADIUS
- eco Sensors Energy Management Software
- Automatic discovery of all PE devices within the same intranet
- Remote real-time power measurement and monitoring
- Remote real-time power outlet management
- Remote real-time environment sensor monitoring
- Plotting/Monitoring of all PE devices
- Exceed threshold alert through SMTP and Syslog
- Power Analysis Report
SKU | PE6108G |
---|---|
Warranty | 2 Years |
Write Your Own Review
More from Aten